Filter Results By:

Products

Applications

Manufacturers

Signal Conditioning

The processing of signals to reduce noise level, amplify, attenuate, or otherwise condition.

See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Generators, Signal Meters, Signal Conditioners


Showing results: 391 - 405 of 489 items found.

  • PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    781345-01 - NI

    102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.

  • PXI Analog Input Module

    NI

    PXI Analog Input Modules feature multiple analog-to-digital converters (ADCs) as well as built-in signal conditioning. Sample rates range from 5 kS/s/ch to 2 MS/s/ch. You can choose from modules that offer up to 28 bits of resolution and up to 32 simultaneous channels. PXI Analog Input Modules offer different types of isolation and filtering, so you can choose options that meet specific application needs. The modules promote increased accuracy, high data throughput, and are ideal for scalable measurement systems with low and high channel counts.

  • 28-CH PPI Module

    ND-6058 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Bluetooth Enabled Signal Conditioners I/O Modules

    microBlox - Acromag, Inc.

    Acromag's microBlox uB Series I/O modules offer a compact, high-performance solution for interfacing sensors and field devices with data acquisition systems. uB signal conditioning modules are ideal to isolate, filter, convert and amplify a wide variety of signal types for test, measurement and control systems. Just plug uB modules into 4, 8, or 16-channel backpanels in any mix for a high-density analog I/O interface. Channel-to-channel isolation provides optimal noise and surge protection from ground loops, spikes, and high common mode voltages.

  • PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device

    779307-01 - NI

    The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.

  • 32-CH 12-Bit 100 kS/s Isolated Analog Input Card

    PCI-9113A - ADLINK Technology Inc.

    ADLINK PCI-9113A is a 32-CH, 12-bit, 100 kS/s isolated analog input card. The PCI-9113A provides analog inputs with 3 programmable input ranges for both bipolar and unipolar inputs. The 32-CH single-ended analog inputs can be converted to 16-CH differential analog inputs, which improve the noise rejection in harsh industrial environments. The analog inputs are isolated from the PC's system ground. This feature not only protects the PC from being damaged from surges on the signal lines, but also eliminates ground loops and common-mode problems commonly seen in industrial measurement applications. The PCI-9113A provides custom circuit area for input signal conditioning. Either signal attenuation or filtering can be applied on per channel basis. With all the features, ADLINK PCI-9113A delivers cost-effective and reliable data acquisition capabilities for ATE, sensor monitoring, data logging, power transmission, and a broad variety of industrial measurement applications.

  • Test Cell Measurement

    Accurate Technologies Inc.

    Accurate Technologies’ long history in powertrain development provided insight into the day-to-day issues that were occurring during engine testing at a time when electronic devices were being introduced to monitor performance instead of traditional mechanical means. Outside of the harsh physical environments, devices used in these applications need to perform difficult high-voltage signal conditioning and high-speed synchronous pulse processing. ATI developed unique products that satisfy specific test cell or dynamometer challenges. These highly accurate products measure engine timing (IGTM) or speed (SmartTach) in convenient ways to provide information that otherwise may not be available.

  • Trace-Level Chemiluminescence NO/NO2/NOx Analyzer

    Model T200U - Teledyne Advanced Pollution Instrumentation

    The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.

  • PXI-6254, 32 AI (16-Bit, 1 MS/s), 48 DIO, PXI Multifunction I/O Module

    779118-01 - NI

    The PXI-6254 offers analog input, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PXI-6251, 16 AI (16-Bit, 1.25 MS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module

    779117-01 - NI

    The PXI-6251 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PCI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device

    779066-01 - NI

    The PCI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PXIe-6259, PXIe, 32 AI (16-Bit, 1.25 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module

    779778-01 - NI

    The PXIe-6259 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PXI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module

    779629-01 - NI

    The PXI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PCI-4462, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 4-Input Sound and Vibration Device

    779309-01 - NI

    The PCI‑4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy, frequency-domain measurements. The PCI‑4462 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications for dynamic signal acquisition devices include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.

  • SLSC and CRIO Modules and Accessories

    Bloomy Controls, Inc.

    Our approach to delivering a high-quality Aerospace, Automated Test Equipment (ATE) asset begins with leveraging National Instruments hardware and software standard platforms. Beginning with high quality instrument platforms for standard Input and Output (I/O), we leverage NI’s PXI and Compact RIO platforms. Extending these system is NI’s unique platform for Switching, Loads and Signal Conditioning (SLSC), which allow the standard I/O to be customized for high performance aerospace industry applications.

Get Help